  07 Sep 17 00:02, you wrote to all:  
    
   RW> + 06 Sep 23:51:53 MAX Begin, v3.01 (task=1)  
   RW> ! 06 Sep 23:51:53 MAX SYS0032: Cannot open com port (com1)  
   RW> ! 06 Sep 23:51:53 MAX Communications driver not properly installed  
    
   RW> However, whenever I run Maximus/2 in WFC mode, I do not get the above  
   RW> error message.  
    
  Do you have the port-sharing parameter added to your SIO command line in  
  CONFIG.SYS?  
    
  ie:  
    
  DEVICE=C:\\SIO\\SIO.SYS (COM1,3F8,IRQ4,-) (COM2,2F3,IRQ3,-)  
  (COM3,INTERNET:3E8,NONE:IRQ4,-) (COM4,INTERNET:2E8,NONE:IRQ3,-)  
    
  This is for a standard COM1 and COM2, and virtual COM3 and COM4. The dash  
  (-)  
  parameter enables sharing the port between applications.  
    