HI Sean, On Sat 2039-Apr-02 23:51, Sean Dennis (1:18/200) wrote to Richard Webb: RW> I hate switching power supplies. I know, they're RW> cleaner than they used to be, but that noise you describe is RW> consistent with their behavior. SD> My dad has an Alinco power supply where he can "dial out" the noise SD> that the PS causes. It's pretty neat. I've heard of those, and a couple of guys i talked to with them really liked them. I'm using this 70 ah Astrong monster over here. Wish they'd made it rack mountable Another thought, maybe we're blaming the wrong switching ps for some of your noise issues. Where's your shack in relation to your computers? RW> Get you a bigger gel cell and float charge it with a trickle charger, RW> I bet that'll clean up a lot. SD> I wish I'd not given away the other batteries I'd received; I could SD> have put two of them together for more amperage. I'm wanting a SD> particular charger - around $100 - that will work especially well SD> with gel cells. The charger will limit the voltage to around 13.4 SD> volts and then trickle down the charge to make sure each cell has SD> 2.4v without "burning" the cell with higher amperage. That would be nice. I wish I could find myself enough change to afford that WEstmountain radio powergate. Provides such a charger, plus relays that when the mains power goes automatically switches you to your battery bnk from your power supply, otherwise floats the gels. WE had our own system partially rigged up at University hospital NEw ORleans, had to do it on the sly for various reasons, so the limitation was when I could put money in. But, I'd still hook the hf up to one of the hospital's gels and run my net from it then charge it back up for a couple days. SD> Of course, once I start working, I'll have money for all of these SD> toys. :) There's always that too. Trouble is, when I do work my business takes every dime I make, but that's an investment in the future, so I'm not complaining, just stating a fact . I think I'll take a $50 as mad money to the hamfest next weekend, and that's it . RW> OH btw, if you've got aluminum wiring, inspect all your RW> fixtures, make sure that they used those little pigtail RW> splices to that aluminum wire that are made for the purpose. RW> electrolytic action or intaction between the copper and the aluminum RW> can be a dangerous thing, and you might find your home sweet home RW> becomes an inferno. IF fixtures aren't connected with those little RW> pigtails made for the purpose get 'em. SD> I did not know that but I can safely tell you that none of these SD> outlets in here use those because "maintenance" is a foreign concept SD> to my landlord. Better check it out then!! Aluminum wiring with fixtures designed for copper can be a real hazard. Expansion is different for aluminum than for copper. IF you can find it on such sites as rtfm.mit.edu the electrical wiring faq, I think it's under /pub/usenet-by-group/alt-home-repair but might be wrong, but the electrical wiring faq discusses it. There are little pigtails that you can buy to attach to that alumnium wiring, other end for connection to fixtures intended for copper. Ask at your favorite electrical supply imporium, and go diy, the life and property you save might be yours. i rewired a mobile home completely from the distro box, using armored BX on the surfaces of the walls instead of trying to work with the aluminum stuff inside the walls. Regards, Richard --- timEd 1.10.y2k+ * Origin: (1:116/901)
|