   Neon John to New Guy   
   Re: Need help with PV to power an air co   
   18 May 15 08:05:56   
   
   From: no@never.com   
      
   On Sat, 16 May 2015 14:38:40 -0500, New Guy  wrote:   
      
   >On Sat, 16 May 2015 13:16:00 -0400, Vaughn wrote:   
      
   >> Honestly, to do what you want to do with solar power you need to start   
   >> all over.  You need far more and better solar panels with an appropriate   
   >> charge controller, you need a much better inverter, and likely you need   
   >> heavier batteries and cables.   
      
   The modified square wave inverter output will be fine.  The problem   
   here centers around the batteries.  Like trying to use a firecracker   
   to bust up a boulder.   
      
   To run a 4000 watt load at 24 volts (don't even think about 12 volts),   
   your battery system must supply 167 amps and do so with sufficiently   
   low internal impedance that there is little voltage sag.   
      
   Starting that compressor might require as much as 4X running load so   
   plan accordingly.   
      
   You'll want several sets of 12 volt deep cycle batteries connected in   
   series and the sets connected in parallel.  I recommend deep discharge   
   AGM batteries by a major name brand such as Sorensen.  If you don't   
   have the $$$ then wet batteries from a reputable company such as   
   Trojan will do but won't last nearly as long.   
      
   If a compressor cycle lasts 5 minutes then 333 watt-hours have been   
   consumed.  Your solar system must replenish that much energy (plus   
   losses) before the next compressor cycle.  A very hefty and expensive   
   proposition.   
      
   If you are working where either electric power isn't available or it   
   isn't available in sufficient quantity to run the compressor, you'll   
   be vastly better off using a conventional engine-powered compressor.   
      
   John   
      
      
   John DeArmond   
   http://www.neon-john.com   
   http://www.fluxeon.com   
   Tellico Plains, Occupied TN   
   See website for email address   
      