Forums before death by AOL, social media and spammers... "We can't have nice things"
|    alt.energy.homepower    |    Electrical part of living of the grid    |    2,576 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 2,440 of 2,576    |
|    Jim Wilkins to All    |
|    Re: Non-linear loads on inverters    |
|    16 May 22 13:41:10    |
      From: muratlanne@gmail.com              "Jim Wilkins" wrote in message news:t5tkpe$qeq$1@dont-email.me...              Briefly. to measure all currents there's a voltmeter and bidirectional       ammeter in the battery cable and optional unidirectional ammeters in the       charging and load leads. The battery meter also displays the integration of       discharging minus charging amps, so ideally at full charge it reads 0.00 AH       and at full discharge it shows the battery's Amp-Hour capacity, which you       can enter as OAH to make the percentage correct.              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]