   Jim Wilkins to All   
   Re: Non-linear loads on inverters   
   16 May 22 13:41:10   
   
   From: muratlanne@gmail.com   
      
   "Jim Wilkins"  wrote in message news:t5tkpe$qeq$1@dont-email.me...   
      
   Briefly. to measure all currents there's a voltmeter and bidirectional   
   ammeter in the battery cable and optional unidirectional ammeters in the   
   charging and load leads. The battery meter also displays the integration of   
   discharging minus charging amps, so ideally at full charge it reads 0.00 AH   
   and at full discharge it shows the battery's Amp-Hour capacity, which you   
   can enter as OAH to make the percentage correct.   
      