   Message 1,363 of 2,547   
   Andrew Gabriel to J.B. Wood   
   Re: POTS Battery Grounding   
   03 Nov 14 15:10:45   
   
   From: andrew@cucumber.demon.co.uk   
      
   In article ,   
   	"J.B. Wood"  writes:   
   > Hello, everyone.  Historically (at least in the U.S.), the positive   
   > terminal of the 48-volt battery stack at the central office is   
   > intentionally connected to an earth ground.  I can't seem to find any   
   > info on why this is necessary or how it improves/facilitates the   
   > operation of a traditional analog common battery telephone system.   
   > Thanks for your time and comment.  Sincerely,   
      
   It's done that way so that any water leak into the cable bundles   
   or connections which results in electrolysis between the connections   
   and ground doesn't cause the metal conductors to be corroded away.   
      
   --   
   Andrew Gabriel   