Forums before death by AOL, social media and spammers... "We can't have nice things"
|    alt.engineering.electrical    |    Electrical engineering discussion forum    |    2,548 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 1,561 of 2,548    |
|    DaveC to All    |
|    Re: Multi-conductor control cable: PVC v    |
|    17 Nov 15 20:45:05    |
      XPost: sci.electronics.components, sci.electronics.design, sci.e       ectronics.repair       From: not@home.cow              > I have forty years experience in designing and building machine tool,       > robotic and automations systems. Whenever I require a cable that might be       > exposed to oil or coolant contamination, or will encounter high rates of       > flexing I only specify Olflex. It's more expensive than most, but a lot       > less expensive than failure and replacement.              I appreciate that this is, enviably, wonderful cable. But it comes in minimum       size of 20 awg. If only it met all my requirements.              My need is for a hand-controller (think Atari joystick)–carrying milliamps.       20 awg is overkill at the expense of weight, diameter, and (arguably) greater       flexibility.              Thanks.              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]