   Syd Rumpo to Jeff Liebermann   
   Re: Replacement LED?   
   22 Mar 16 09:10:13   
   
   XPost: sci.electronics.components, sci.electronics.design, sci.e   
   ectronics.repair   
   From: usenet@nononono.co.uk   
      
   On 22/03/2016 03:51, Jeff Liebermann wrote:   
      
      
      
   > I beg to differ with your diagnosis.  Unless the LED has magically   
   > turned into a thermostat controlled flasher, it's not going to do   
   > that.   
      
   Thermostat controlled flasher is probably the exact description. It   
   happens when LEDs are driven straight from batteries too, and is   
   probably the bond wire heating and cooling making intermittent contact   
   at a few Hz.   
      
   I have a cheap LED torch which uses nine parallel connected white LEDs   
   running directly from 3 AAs.  After a battery replacement, one is out,   
   four flash at different rates, and four are on.   
      
      