|    Pasieka to All    |
|    run capacitor sizing ? cannot determine     |
|    26 Jul 22 06:01:26    |
      From: 1e8dbacd6cbe854c1c2e33544319180f@example.com              looking for a run capacitor to the 5 HP Doerr motor powering the families air       compressor... no-one knows or has documentation as to what is supposed to       be... and the cap in it is rusted beyond legibility. compressor is Emglo model       Y5B-80V serial        102588029 powered by a Doerr 5HP Motor 5 hp probably made 1988 as that is when       the pressure tank was made. the UL and CSA file on it is LR13758 label reads:       5HP 1 Phase 1740 Rpm m184t frame Mtr ref: r75334af881 thinking this is like a       model number...        60Hetz, 230 volts, 23.0 amps, SF amps 24.5, SF 1.15 insulation class BR type       TX KVA code G and then a final long number in the bottom right that is not       labeled is 20(B or 8)046370200 ....it says everything but does not tell me the       capacitor sizes. would        appreciate a call if someone can educate me on this.. wife is pissed the       compressor is still preventing me from finishing cleaning the garage... I am       at the point where I want to simply measure current draw and try to dial in a       size iteratively. however,        I am not sure what my target characteristic setup should be and I am hoping       you would advise 773-2258558 is my cell Mark...I used formulas from websites       and calculated 98uF if its 84 percent efficient and 91uF if its 78 percent       efficient but the        efficiency is not specified and I dont know how to extract it from the data       available... more importantly another website says a 5hp run cap is never over       40uF so I am begging for help.. will venmo or quickpay BEER MONEY! already       replaced bearing and        cleaned and painted this compressor up..       snippits from emails I sent to allot of people that may be applicable but       basically someone has this motor and if they could remove the cover and tell       me what the cap is supposed to be I WOULD LOVE YOU FOR IT              since the efficiency is not specified on the label I am uncomfortable doing       the calculation with a 75percent approximation which also gives me an       uncomfortable 88.14uF Capacitor and it goes up from there...98.71uF for 84       percent efficiency using this        formula....              The single-phase capacitance C(µF) in microfarad is equal to 1000 times the       product of power P(W) in watts and efficiency η divided by the product of       voltage V(V) in volts square and the frequency F(Hz). The formula for       calculating capacitor value is              C(µF) = (P(W) x η x 1000) / (V(V) x V(V) x f)              found on this website calculator:              Single phase Motor Capacitor Calculation calculator | Electrical4u              Maybe this was supposed to be a starting capacitance? but what's in there now       is much bigger. This has been occupying my mind for months       and months', searching for a solution...wife is going nuts so i have to finish       this compressor off to finish the garage clean up... thinking of trying a 30       uF and then increasing receiving current draw by trial and error on the two       legs of the single        phase electrical connection and searching for the capacitance value resulting       in smallest current but I am just guessing at this point ... what I am       thinking is the motor actually spun over in the winter with the blown       capacitor so as long as I do not        exceed the capacitance I believe I won't damage the motor, I really would       appreciate learning a good method of getting to a value as this is not the       first time in my life this would have been useful and I'm pretty sure it won't       be the last..... I am in a        dangerous state, I don't know what I don't know.       https://www.polytechforum.com/img/n9n       https://www.polytechforum.com/img/n9p       https://www.polytechforum.com/img/n9r       https://www.polytechforum.com/img/n9t       https://www.polytechforum.com/img/n9v       https://www.polytechforum.com/img/n9x              --       For full context, visit https://www.polytechforum.com/electrical       run-capacitor-sizing-cannot-determine-original-size-and-no-1550939-.htm              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
(c) 1994, bbs@darkrealms.ca