Forums before death by AOL, social media and spammers... "We can't have nice things"
|    alt.engineering.electrical    |    Electrical engineering discussion forum    |    2,547 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 2,408 of 2,547    |
|    Dimitris Tzortzakakis to All    |
|    Re: run capacitor sizing ? cannot determ    |
|    02 Aug 22 15:03:48    |
      From: noone@nospam.com              Στις 1/8/2022 11:18 μ.μ., ο/η gfretwell@aol.com έγραψε:       > On Mon, 01 Aug 2022 19:01:35 +0000, Pasieka       > <1e8dbacd6cbe854c1c2e33544319180f@example.com> wrote:       >       >> BEll curve...That's is a useful insight thank you... wanted to get some       data logging current meters and rpm meters to work together so I can plot and       get a better idea of iterative capacity values and performance / operational       chacteristics.. was        going to do the pump as a load without building pressure until I get closer to       what I am hoping the correct value will be... thinking back emf voltage on the       capacitor would also be relavent but do not know what to expect... maybe I       will collect data on        another working compressor with a 3 hp motor i have access too and know the       original capacitor values of and then start working on the 5 hp..... any       advice is appreciated... need to get a student copy of labview and get my       daughter to install it... it's        been years.. wonder if I will remember how to do the DAta acquisition... and I       my old NI USB-6008 can still be used or if it's to old for current support....       >       > I was playing with my 3HP compressor in a similar situation. The run       > cap burnt beyond recognition. I had a box of capacitors and used the       > trial and error method to pick a size based on current draw at about       > half the rated pressure., That seems to be when it actually draws the       > most. As the pressure starts reaching max the current actually drops       > because you are moving less air and doing less work. That is similar       > to why a vacuum cleaner actually speeds up when you block the air       > flow.       > I started around 40 MFD as I recall and ended up at 50.       google is your friend.              https://air-compressor-help.com/how-to-size-a-run-capacitor-for-air-compressor/       https://www.google.com/search?q=how+to+calculate+run+capacitor+s       ze+for+a+compressor&rlz=1C1GIWA_enGR882GR882&oq=how+to+calculate       &aqs=chrome.2.69i57j0i512j69i59j0i512l7.15053j0j7&sourceid=chrome&ie=UTF-8              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
(c) 1994, bbs@darkrealms.ca