home bbs files messages ]

Forums before death by AOL, social media and spammers... "We can't have nice things"

   alt.engineering.electrical      Electrical engineering discussion forum      2,547 messages   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]

   Message 948 of 2,547   
   Tom Biasi to Kissi Asiedu   
   Re: 60Hz to 50Hz Appliance   
   05 Oct 13 10:29:44   
   
   From: tombiasi@optonline.net   
      
   On 10/5/2013 9:29 AM, Kissi Asiedu wrote:   
   > Hello,   
   > I was wondering if an American Made Referigrator rated 120V 60Hz could   
   > work efficiently with the use of a step down transformer in Africa where   
   > the electricity is rated at 240V 50Hz.   
   > Thanks,   
   It's not recommended to do so. The motor will not perform as intended.   
      
   --- SoupGate-Win32 v1.05   
    * Origin: you cannot sedate... all the things you hate (1:229/2)   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]