Forums before death by AOL, social media and spammers... "We can't have nice things"
|    comp.sys.ibm.ps2.hardware    |    Discussing IBM PS/2 hardware    |    42,985 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 41,592 of 42,985    |
|    Carsten Lyng to All    |
|    Re: Forlorn hope Re: Error 00240100, Onb    |
|    29 Mar 23 06:13:55    |
      From: askevej37a@gmail.com              onsdag den 29. marts 2023 kl. 13.51.40 UTC+2 skrev Louis Ohland:       > Can you change the monitor and cable? We do forlorn hopes here all the        > time...        >        > Screen artifacts? Lines? Characters?        >        > Can you give us the advanced diagnostics error code [not that it fixes        > anything]?        >        > "XGA-2 graphics enabled with ISO 9241-3 when coupled with compliant        > display and operating system"        >        > After repeated "Beatings By Helga" (TM), my memory is kaotic, but some        > snippets that XGA-2 prefers 95xx monitors. This does not mean 85xx        > monitors won't work, but the 95xx support a wider range of resolutions.        > This by itself is not the smoking gun, but IBM developed the monitor ID        > function where the very limited circuitry [two resistors?] is in the        > monitor.        >        > Are you using a CRT or LED monitor? CRT will possumbly have the monitor ID.       > Carsten Lyng wrote:        > > When the machine starts, I get this error code 00240100        > > and the machine boots into the Ref / diagnostic screen.        > >        > > When I run diagnostics on the machine, the onboard XGA-2 is fails the       test.        > > ( have the unit serviced )        > >        > > I´am not able to boot to dos, because the machine boots to the Ref /       Diagnostics screen.        > >        > > There are a few screen artifacts, when the system is power on, but only in       a second or so.        > > Is there any way to disable the onboard XGA-2 and use another graphics       card in one of the MCA slots ?. (XGA-2 perhaps ? )        > >        > > It is a nice SLC3 planar, and it would be great if the machine could be       used, even it has got problems with the onboard XGA-2        > >        > > The planar is.: FRU P/N 65G9714        > >                     Hi Louis,              Let´s keep up the hope up:-)              The arifacts are small blue dots in the top of the screen, I will see if i can       take a picture of them       I´am using a LED monitor at the moment, I can borrow a CRT monitor and VGA       cable from a friend, and        try with that one.        Will also run the diagnostics on the machine, and give you the error codes.              Can also try with a XGA-2 card from one of my other machines, and see if I can       make it boot to dos by       pressing F1.              I will see if I get time for it later, or tomorrow.                     Thanks for the help        /Carsten              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
(c) 1994, bbs@darkrealms.ca