home bbs files messages ]

Forums before death by AOL, social media and spammers... "We can't have nice things"

   comp.sys.ibm.ps2.hardware      Discussing IBM PS/2 hardware      42,985 messages   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]

   Message 42,546 of 42,985   
   Louis Ohland to All   
   @6014.ADF "Standard Microsystems Corpora   
   24 Jan 24 08:39:07   
   
   From: ohland@charter.net   
      
   ARCNET-PS310 Configuration Diskette Program   
   SMC part number 130.090501            v3.00   
   File @6014.adf   
   Version 2.0 Rev C   
   Bob Galazka 02-05-92   
   AdapterID 06014h   
   AdapterName  "Standard Microsystems Corporation ARCNET-PS110/210/310"   
   NumBytes 4   
   nameditem   
            Prompt  "RAM Buffer Base Address"   
              Choice "Segment D000" pos[0]=1000XXXXb mem 0d0000h-0d1fffh   
              Choice "Segment D200" pos[0]=1001XXXXb mem 0d2000h-0d3fffh   
              Choice "Segment D400" pos[0]=1010XXXXb mem 0d4000h-0d5fffh   
              Choice "Segment D600" pos[0]=1011XXXXb mem 0d6000h-0d7fffh   
              Choice "Segment D800" pos[0]=1100XXXXb mem 0d8000h-0d9fffh   
              Choice "Segment DA00" pos[0]=1101XXXXb mem 0da000h-0dbfffh   
              Choice "Segment DC00" pos[0]=1110XXXXb mem 0dc000h-0ddfffh   
              Choice "Segment DE00" pos[0]=1111XXXXb mem 0de000h-0dffffh   
              Choice "Segment C000" pos[0]=0000XXXXb mem 0c0000h-0c1fffh   
              Choice "Segment C200" pos[0]=0001XXXXb mem 0c2000h-0c3fffh   
              Choice "Segment C400" pos[0]=0010XXXXb mem 0c4000h-0c5fffh   
              Choice "Segment C600" pos[0]=0011XXXXb mem 0c6000h-0c7fffh   
              Choice "Segment C800" pos[0]=0100XXXXb mem 0c8000h-0c9fffh   
              Choice "Segment CA00" pos[0]=0101XXXXb mem 0ca000h-0cbfffh   
              Choice "Segment CC00" pos[0]=0110XXXXb mem 0cc000h-0cdfffh   
              Choice "Segment CE00" pos[0]=0111XXXXb mem 0ce000h-0cffffh   
            Help   
             "Select one of these base addresses for the ARCNET Controller's   
             RAM buffer.  Be sure the address you select has not been   
             used by any other expansion card (a conflict is indicated by   
             an asterisk)."   
   nameditem   
            Prompt  "I/O Port Address Range"   
              Choice "02E0-02E7" pos[1]=XXXX0000b io 02e0h-02e7h   
              Choice "0300-0307" pos[1]=XXXX0001b io 0300h-0307h   
              Choice "0350-0357" pos[1]=XXXX0010b io 0350h-0357h   
              Choice "1988-198F" pos[1]=XXXX0011b io 1988h-198fh   
              Choice "2010-2017" pos[1]=XXXX0100b io 2010h-2017h   
              Choice "5678-567F" pos[1]=XXXX0101b io 5678h-567fh   
              Choice "5900-5907" pos[1]=XXXX0110b io 5900h-5907h   
              Choice "8088-808F" pos[1]=XXXX0111b io 8088h-808fh   
              Choice "8910-8917" pos[1]=XXXX1000b io 8910h-8917h   
              Choice "9C80-9C87" pos[1]=XXXX1001b io 9c80h-9c87h   
              Choice "ADB8-ADBF" pos[1]=XXXX1010b io 0adb8h-0adbfh   
              Choice "B4E8-B4EF" pos[1]=XXXX1011b io 0b4e8h-0b4efh   
              Choice "BAD8-BADF" pos[1]=XXXX1100b io 0bad8h-0badfh   
              Choice "D0D0-D0D7" pos[1]=XXXX1101b io 0d0d0h-0d0d7h   
              Choice "E8D0-E8D7" pos[1]=XXXX1110b io 0e8d0h-0e8d7h   
              Choice "F8E8-F8EF" pos[1]=XXXX1111b io 0f8e8h-0f8efh   
            Help   
             "Select one of these address ranges for the ARCNET Controller's   
             I/O Ports.  Be sure the address range you select has not been   
             used by any other expansion card (a conflict is indicated   
             by an asterisk)."   
   nameditem   
            Prompt  "Interrupt Level"   
              Choice  "IRQ 2 (9)"  pos[0]=XXXX100Xb int 9   
              Choice  "IRQ 3"      pos[0]=XXXX000Xb int 3   
              Choice  "IRQ 4"      pos[0]=XXXX001Xb int 4   
              Choice  "IRQ 5"      pos[0]=XXXX010Xb int 5   
              Choice  "IRQ 7"      pos[0]=XXXX011Xb int 7   
              Choice  "IRQ 10"     pos[0]=XXXX101Xb int 10   
            Help   
             "Select an Interrupt Level for the ARCNET Controller.   
              It is strongly recommended that you select an Interrupt   
              Level that has not been used by any other expansion card."   
   nameditem   
            Prompt  "Node Address High Digit"   
              Choice  "F" pos[2]=1111XXXXb   
              Choice  "E" pos[2]=1110XXXXb   
              Choice  "D" pos[2]=1101XXXXb   
              Choice  "C" pos[2]=1100XXXXb   
              Choice  "B" pos[2]=1011XXXXb   
              Choice  "A" pos[2]=1010XXXXb   
              Choice  "9" pos[2]=1001XXXXb   
              Choice  "8" pos[2]=1000XXXXb   
              Choice  "7" pos[2]=0111XXXXb   
              Choice  "6" pos[2]=0110XXXXb   
              Choice  "5" pos[2]=0101XXXXb   
              Choice  "4" pos[2]=0100XXXXb   
              Choice  "3" pos[2]=0011XXXXb   
              Choice  "2" pos[2]=0010XXXXb   
              Choice  "1" pos[2]=0001XXXXb   
              Choice  "0" pos[2]=0000XXXXb   
            Help   
             "Each ARCNET Controller must be assigned a unique node   
             address or node ID in the range 01 to FF hexadecimal   
             (1 to 255 decimal).  Select one of these addresses for   
             the most significant hexadecimal digit. Selecting 00   
             will disable the PS310 ARCNET Controller. Do not select   
             00 for a PS110 or PS210 ARCNET Controller."   
   nameditem   
            Prompt  "Node Address Low Digit"   
              Choice  "F" pos[2]=XXXX1111b   
              Choice  "E" pos[2]=XXXX1110b   
              Choice  "D" pos[2]=XXXX1101b   
              Choice  "C" pos[2]=XXXX1100b   
              Choice  "B" pos[2]=XXXX1011b   
              Choice  "A" pos[2]=XXXX1010b   
              Choice  "9" pos[2]=XXXX1001b   
              Choice  "8" pos[2]=XXXX1000b   
              Choice  "7" pos[2]=XXXX0111b   
              Choice  "6" pos[2]=XXXX0110b   
              Choice  "5" pos[2]=XXXX0101b   
              Choice  "4" pos[2]=XXXX0100b   
              Choice  "3" pos[2]=XXXX0011b   
              Choice  "2" pos[2]=XXXX0010b   
              Choice  "1" pos[2]=XXXX0001b   
              Choice  "0" pos[2]=XXXX0000b   
            Help   
             "Each ARCNET Controller must be assigned a unique node   
             address or node ID in the range 01 to FF hexadecimal   
             (1 to 255 decimal).  Select one of these addresses for   
             the least significant hexadecimal digit. Selecting 00   
             will disable the PS310 ARCNET Controller. Do not select   
             00 for a PS110 or PS210 ARCNET Controller."   
   nameditem   
            Prompt  "Network Timeout Parameter"   
              Choice  "Normal"  pos[1]=11XXXXXXb   
              Choice  "Med L"   pos[1]=10XXXXXXb   
              Choice  "Med H"   pos[1]=01XXXXXXb   
              Choice  "Maximum" pos[1]=00XXXXXXb   
            Help   
             "Select one of these addresses for the ARCNET Controller's   
             Timeout Parameter.  Be sure to select the same parameter   
             for all the controllers on the network.  Under normal   
             circumstances, select ."   
   nameditem   
            Prompt "PROM Socket Base Address"   
              Choice "PROM NOT USED" pos[3]=XXX00000b   
              Choice "Segment D000 " pos[3]=XXX11000b mem 0d0000h-0d1fffh   
              Choice "Segment D200 " pos[3]=XXX11001b mem 0d2000h-0d3fffh   
      
   [continued in next message]   
      
   --- SoupGate-Win32 v1.05   
    * Origin: you cannot sedate... all the things you hate (1:229/2)   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]


(c) 1994,  bbs@darkrealms.ca