home bbs files messages ]

Forums before death by AOL, social media and spammers... "We can't have nice things"

   comp.sys.ibm.ps2.hardware      Discussing IBM PS/2 hardware      42,985 messages   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]

   Message 42,755 of 42,985   
   Louis Ohland to All   
   H12989 POTENTIAL UNDETECTED DATA MODIFIC   
   06 Jan 25 21:47:41   
   
   From: ohland@charter.net   
      
     1.4.378 POTENTIAL UNDETECTED DATA MODIFICATION ON 9585   
      
         Record number:        H12989   
      
           Device:               D/T9585   
           Model:                M   
           Tip key:   
           Date created:         O93/08/23   
           Date last altered:    A94/08/15   
      
        SYMPTOM:   
         WHEN AN IBM SERVER 85 IS CONFIGURED WITH A DATA STREAMING   
         ADAPTER, AND THE ADAPTER'S DATA STREAMING MODE IS IN USE,   
         DATA LOSS OR DATA MODIFICATION MAY RESULT WITH NO ERROR   
         MESSAGE TO THE USER.   
      
         TESTING HAS SHOWN THIS EXPOSURE EXISTS WHEN A LANSTREAMER   
         MC 32 ADAPTER OR ETHERSTREAMER MC 32 ADAPTER IS INSTALLED   
         IN THE 9585.   
      
        PROBLEM ISOLATION AIDS:   
         - IBM LANSTREAMER MC 32 ADAPTER:   
           FRU P/N92F8941, OPTION 92F8942, FEATURE CODE 8942 OR 1100   
         - IBM ETHERSTREAMER MC 32 ADAPTER:   
           FRU P/N59G9081, OPTION 59G9066, FEATURE CODE 9066 OR 3310   
      
        FIX:   
         A CIRCUMVENTION IS TO TURN OFF THE LAN STREAMER OR   
         ETHERSTREAMER ADAPTER'S DATA STREAMING FUNCTION USING   
         "CHANGE CONFIGURATION."  IF A DATA STREAMING ADAPTER IS   
         NOT INSTALLED IN THE SERVER 85, NO ACTION IS REQUIRED.   
      
         A PERMANENT SOLUTION IS BEING INVESTIGATED.  THIS TIP WILL   
         BE UPDATED AS NEW INFORMATION DEVELOPS.   
      
         IBM IS TAKING IMMEDIATE ACTION TO NOTIFY POTENTIALLY   
         AFFECTED CUSTOMERS OF THIS SITUATION.   
         2/08/94 UPDATE:   
         Corrected Lan Streamer adapters are now shipping and the rollout   
         of adapters will continue over the next 90 days.  There are new   
         part numbers and FRU numbers associated with these adapters   
         Any adapter with the old FRU number needs to be replaced.   
      
         To register the adapters for replacement, call 1-800-426-2269   
         from 9: 00 AM to 8: 00 PM EST.  These adapters will be replaced   
         free of charge. Following is a list of associated part numbers   
         and FRU numbers.   
      
          ADAPTER NAME   OLD PART#   NEW PART#    OLD FRU#    NEW FRU#   
      
          LANStreamer 32  92F8942     74G0103    P/N92F8941  P/N74G0098   
          LANStreamer 16  59G8998     74G0801    P/N58G8999  P/N74G0800   
          EtherStreamer   59G9066     74G0850    P/N59G9081  P/N74G0865   
      
         Additional information for this problem is also contained in   
         RETAIN Record H122376.   
      
   --- SoupGate-DOS v1.05   
    * Origin: you cannot sedate... all the things you hate (1:229/2)   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]


(c) 1994,  bbs@darkrealms.ca