|    Computer Nerd Kev to Ian Field    |
|    Re: Monitor Sync Signal in 80s Arcade Ma    |
|    21 Feb 13 07:16:57    |
      From: not@telling.you              On 21 Feb 2013, Ian Field wrote:              > In equipment like a VDU, where there are pulsed currents       > above the hearing frequency - electrolytics suffer a lot of       > ripple current, the weak ones will get noticeably warm - or       > even hot.       >       > Your sense of touch could save you the cost of an ESR meter       > - but the aluminium can isn't isolated, so rail decouplers       > on negative rails will be live.              I presume I could use an infared temperature sensor to do the       same job while keeping my fingers out of zapping range?              --       __ __       #_ < |\| |< _#              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]