Forums before death by AOL, social media and spammers... "We can't have nice things"
|    comp.sys.raspberry-pi    |    Raspberry Pi computers & related hardwar    |    26,127 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 25,044 of 26,127    |
|    druck to John Aldridge    |
|    Re: 1-wire behaviour on Bookworm    |
|    20 Sep 24 21:38:09    |
      From: news@druck.org.uk              On 20/09/2024 11:17, John Aldridge wrote:       [Reading ds18b20 sensors in parallel]       > No, but AIUI the "right" way to do this is to send the text "trigger" to       > /sys/bus/w1/devices/w1_bus_master1/therm_bulk_read before reading the       > values as normal. The trigger causes them all to start a conversion at       > once, following which the reads all complete immediately once a single       > conversion time has elapsed.       >       > As a quick hack, try executing the following before reading your       > sensors...       >       > sudo su < |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]