      You need a 90 meg if coming off an X 10 probe, 99 to the        BNC.I think.               Off the top of my head I think you'll be down to 1/10th the upper limit       bandwidth, and on AC coupling it will take much longer to settle to the center       is there's DC on the input. Also not that in most scope front ends that will       NOT give you 10 X the max        DC input.               The sell X 100 probes, a bit more money per everything else. I used one for       certain things when faced with a scope that lacked 20V/div. Yeah, they gave       you more at the low end but took away from the high end. No more looking at       the collector of an HOT/       LOPT with a X 10 probe.              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |