Forums before death by AOL, social media and spammers... "We can't have nice things"
|    sci.electronics.basics    |    Elementary questions about electronics    |    72,318 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 71,521 of 72,318    |
|    Michael Terrell to George Herold    |
|    Re: Wattage of rough service incandecent    |
|    27 Jan 20 02:32:38    |
      From: terrell.michael.a@gmail.com              On Sunday, January 26, 2020 at 4:00:53 PM UTC-5, George Herold wrote:       > On Saturday, January 25, 2020 at 7:04:53 AM UTC-5, Michael Terrell wrote:       > > On Friday, January 24, 2020 at 8:07:41 AM UTC-5, default wrote:       > > >       > > > On Thu, 16 Jan 2020 10:42:28 -0800 (PST), Michael Terrell wrote:       > > > >       > > > >The TS-382 series were military versions in transit cases. They had a       vibration reed frequency meter to display 60 Hz and 400Hz. The insides were       protected for Jungle use, and the one I have, (TS-382/F)has heat strips to       drive moisture out of the        cabinet.       > > >        > > > I remember those from navy ET-A school. They had two resonant reeds,       > > > for 40 HZ and 400 HZ.       > >        > >        > > I've never seen one for 40 Hz. Only 60Hz or 60Hz and 400Hz.       >        > Niagara Falls use to send out 25 Hz power.. (maybe three phase,       > but I couldn't find a reference.)               Yes, 25Hz was common a century ago, it was used for large motors to get better       torque at low speeds. It was common in mining towns, since it was needed for       the mining equipment. It wasn't produced by military style mobile or portable       generators. The        Sinewave generators had frequency meters for accurate testing of AC line       components. It was common to buy radios, clocks and kitchen appliances made       for 25Hz for the areas that used it. Those radios till show up as antiques,       because they also worked on        60Hz. The same radio was often built in two models, with the regular 60Hz       transformer, or the much larger 25Hz version that cost more. The Military used       60Hz for land based generators and 400Hz for aircraft to reduce the size and       weight of motors and        transformers.              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
(c) 1994, bbs@darkrealms.ca