Forums before death by AOL, social media and spammers... "We can't have nice things"
|    sci.electronics.repair    |    Fixing electronic equipment    |    124,925 messages    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]
|    Message 123,164 of 124,925    |
|    whit3rd to Cursitor Doom    |
|    Re: Scope keeps blowing fuses    |
|    23 Oct 22 14:13:30    |
      From: whit3rd@gmail.com              On Saturday, October 22, 2022 at 7:26:11 AM UTC-7, Cursitor Doom wrote:       > Hi all,       >       > So my main analogue scope, a Tek 2465A, has gone faulty. Keeps blowing       > main fuses (the 2A one on the rear panel). I opened the case and found       > two RIFA caps that had obviously blown, so replaced them, but it's       > still blowing fuses. I can't be 100% certain, but I'm pretty sure       > there's a fault with the PSU board as I get the briefest whiff of       > burning from that area each time I put a new fuse in and power up.              First thing to check is the rectifier; that diode bridge can fail, and       apply AC to the filter capacitors, and... that'll take out the fuse.       Not sure why the RIFA capa goes, though; maybe just a power surge some       time last week?              There seem to be some surge-suppressors (gas discharge?) in the diagram, they       might       have failed short in a surge..              --- SoupGate-Win32 v1.05        * Origin: you cannot sedate... all the things you hate (1:229/2)    |
[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]