   Re: thermal switch   
   07 Feb 24 17:55:33   
   
   From: legg@nospam.magma.ca   
      
   On Wed, 7 Feb 2024 13:35:48 -0800 (PST), "ohg...@gmail.com"   
    wrote:   
      
   >On Wednesday, February 7, 2024 at 1:44:09?PM UTC-5, legg wrote:   
   >> A thermal switch rated 110C/0C - does this mean freezing is   
   >> required to rest it?   
   >>   
   >> Others rated 150C/60C will self-reset at room temp.   
   >>   
   >> RL   
   >   
   >They reset on their own assuming it's a thermostat and not a fuse.   
      
      
   Microwave cabinet sensors swithing 12A 120VAC.   
      
   Same symbol and part family as two other types   
   used w/35C reset, measuring box wall tmps.   
   They test as resetable.   
      
   KSD100LC0   
   PW4261N100   
      
   GE doesn't issue part numbers in service manual.   
      