home bbs files messages ]

Forums before death by AOL, social media and spammers... "We can't have nice things"

   sci.electronics.repair      Fixing electronic equipment      124,925 messages   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]

   Message 124,621 of 124,925   
   ehsjr to Liz Tuddenham   
   Re: Failed water pump and sump query   
   03 Feb 25 18:23:07   
   
   From: ehsjr@verizon.net   
      
   On 2/3/2025 3:05 PM, Liz Tuddenham wrote:   
      
      
      
   >   
   > They are rated for AC only, so most unlikely to be a brush motor (which   
   > might also be too noisy in this application).  If there is no visible   
   > capacitor, it could be an induction-start motor or the capacitor is   
   > hidden in the control box.   
   >   
   > When it starts, is there s "snick!" noise as it reaches running speed?   
   > That would be a centrufugal starting switch throwing out - and when the   
   > motor is switched off,  as it slows down, you might hear the switch go   
   > "Snick! " again as it resets.   
      
   +1   
   Might be an easy repair: Remove bell housing, clean switch contacts.   
   Ed   
      
      
      
   --- SoupGate-DOS v1.05   
    * Origin: you cannot sedate... all the things you hate (1:229/2)   

[   << oldest   |   < older   |   list   |   newer >   |   newest >>   ]


(c) 1994,  bbs@darkrealms.ca